Safety integrity level: |
SILCL3 (IEC 62061) |
Category: |
Category 4 (EN ISO 13849) |
Performance level: |
PL e (EN ISO 13849) |
PFHd: |
3.8 * 1E-09 7.3 * 1E-09 |
TM (mission time): |
20 a |
Functions |
Muting: |
- |
Override: |
- |
Belt stop: |
- |
Concurrence monitoring: |
- |
Monitoring total muting time: |
- |
Sensor gap monitoring: |
- |
End of muting by ESPE: |
- |
Mechanical data |
Dimensions (W x H x D): |
22.5 mm x 96.5 mm x 120.8 mm |
Weight: |
150 g |
Electrical data |
Synchronous time monitoring: |
1,500 ms (at program 3 and 5) |
Protection class: |
EN 61140 |
Power consumption: |
3 W |
Switch-on time of inputs: |
70 ms |
Input voltage HIGH: |
13 V DC ... 30 V DC |
Input voltage LOW: |
-5 V ... 5 V DC |
Input current HIGH: |
2.4 mA ... 3.8 mA |
Input current LOW: |
-2.5 mA ... 2.1 mA |
Response time: |
≤ 17 ms≤ 56 ms 1) |
Number of inputs: |
4 dual-channel or 8 single-channel |
Interfaces |
Connection type: |
Cable gland |
Ambient data |
Connection type: |
Plug-in screw-type terminals |
Enclosure rating terminals: |
IP 20 |
Protection class housing: |
IP 40 |
Ambient operating temperature: |
-25 °C ... 55 °C |
Storage temperature: |
-25 °C ... 70 °C |
Air humidity: |
15 % ... 95 %, non-condensing |
Climate conditions according to: |
EN 61131-2 |
Electromagnetic compatibility (EMC): |
EN 61000 EN 55011 |
Vibration resistance: |
5 g, 5 Hz ... 500 Hz (EN 60068-2-6) |